Order Number: 900139
STAGE | MINIMUM VOLTAGE | SENSOR MEASUREMENTS | DATA TRANSMISSION | NOTE |
1. normal mode | > 6 V | ☑ | ☑ | default (normal) operating mode where the device measures and logs sensors data and transmits the logs to the FieldClimate cloud |
2. gathering mode | 5.8 V – 6 V | ☑ | ☒ | device is only measuring and logging sensors data, it does not have enough power to execute transmission |
3. Sleeping mode | < 5.8 V | ☒ | ☒ | device does not have enough power to measure the sensors or to do the data transmissions |
nMETOS, LoRAIN, LoRATH
a. Supercapacitor board number 29-0410
- supported on motherboards 29-0404 (nMETOS and former LoRAIN) Rev. C. and E only.
- Solar panel is plugged directly into SOL input on the motherboard (29-0404).
- Chart display:
b. Supercapacitor board number 29-0370 (discontinued):
- Supported on the motherboards 29-0404 (nMETOS and former LoRAIN) Rev. B., C., and E.
- Solar panel is plugged into SOL input on the super capacitor PCB (29-0370).
- Chart display:
INFORMATION about PCB REVISION:
Please, refer to Check the version (revision) of the board 29-0404
HOW TO MEASURE THE BATTERY CHARGE:
iMETOS 3.3, ECO D3, µMETOS Clima and Soil NB-IoT & LoRa
a. Using a multimeter:
b. Menu of the device:
To know how to connect to the station using a USB cable, please, refer to: Create Log file with PI Service Terminal iMetos 3.3 & ECO D3
On the main, select (2) SENSORS and then (B) BATTERY STATUS:
NOTE: Ensure the battery is above 6.3V.
nMETOS, LoRAIN, LoRATH
a. Multimeter:
b. Menu of the device:
To know how to connect to the station using a USB cable, please, refer to: Create Log file with PI Service Terminal NB-IoT Stations
On the main menu, select (5) SENSOR TESTING:
NOTE: Ensure the battery has 3.5 or 3.6V and the supercapacitor 2.5V or more. If the battery or the supercapacitor are below the threshold, it is not recommended to use them.