iMETOS 3.3, ECO D3, µMETOS Clima and Soil NB-IoT & LoRa

Order Number: 900139

STAGEMINIMUM VOLTAGESENSOR MEASUREMENTSDATA TRANSMISSIONNOTE
1. normal mode> 6 Vdefault (normal) operating mode
where the device measures and logs
sensors data and transmits the logs
to the FieldClimate cloud
2. gathering mode5.8 V – 6 Vdevice is only measuring and logging
sensors data, it does not have
enough power to execute
transmission
3. Sleeping mode< 5.8 Vdevice does not have enough power
to measure the sensors or to do the
data transmissions


nMETOS, LoRAIN, LoRATH


a. Supercapacitor board number 29-0410

  • supported on motherboards 29-0404 (nMETOS and former LoRAIN) Rev. C. and E only.
  • Solar panel is plugged directly into SOL input on the motherboard (29-0404).
  • Chart display:



b. Supercapacitor board number 29-0370 (discontinued):

  • Supported on the motherboards 29-0404 (nMETOS and former LoRAIN) Rev. B., C., and E.
  • Solar panel is plugged into SOL input on the super capacitor PCB (29-0370).
  • Chart display:




INFORMATION about PCB REVISION:

Please, refer to Check the version (revision) of the board 29-0404


HOW TO MEASURE THE BATTERY CHARGE:


iMETOS 3.3, ECO D3, µMETOS Clima and Soil NB-IoT & LoRa


a. Using a multimeter:


b. Menu of the device:

To know how to connect to the station using a USB cable, please, refer to: Create Log file with PI Service Terminal iMetos 3.3 & ECO D3


On the main, select (2) SENSORS and then (B) BATTERY STATUS:


NOTE: Ensure the battery is above 6.3V.


nMETOS, LoRAIN, LoRATH


a. Multimeter:



b. Menu of the device:

To know how to connect to the station using a USB cable, please, refer to: Create Log file with PI Service Terminal NB-IoT Stations


 On the main menu, select (5) SENSOR TESTING:


NOTE: Ensure the battery has 3.5 or 3.6V and the supercapacitor 2.5V or more. If the battery or the supercapacitor are below the threshold, it is not recommended to use them.