Prior to use, verify the product arrived in good condition.

Connect to METOS 5 and µMETOS
Input:
SDI-12
Input:
PW = Vcc (red) DT = Data (white) GR = Ground (green)
Connect to iMETOS 3.3 and ECO D3
Interface required: 29-0285 (internal) or 29-0373 (external)
Connect the interface 29-0285
Input:
EXT (iMETOS 3.3) EXT1 (ECO D3)

Connect the sensor to the interface 29-0285
Input:
Channel A Channel B
Wiring:
DT = Data (white) PW = Vcc (red) GD = Ground (green)

Connect the interface 29-0373
Input:
RS485 (iMETOS 3.3) SENS. CHAIN (ECO D3)
Wiring:
BR = Brown GR = Green YE = Yellow WH = White BR = Bare

Connect the sensor to the interface 29-0373
Input:
SDI12
Wiring:
SUP = Vcc (red) DT = Data (white) GND = Ground (green)

Connect to RadioNode
RFRN13 iMETOS RadioNode Drill & Drop
SD51 iMETOS RadioNode Drill & Drop
Order number 700243 (EU 869MHZ) / 700244 (US 915MHZ)

If you have any questions or need additional help, please submit a ticket to our Support team at METOS® support center.