Sentek Drill & Drop - Wiring Diagram

Modified on Fri, 7 Nov at 11:51 AM

Prior to use, verify the product arrived in good condition.



Connect to METOS 5 and µMETOS

Input:

SDI-12

Input:

PW = Vcc (red)
DT = Data (white)
GR = Ground (green)



Connect to iMETOS 3.3 and ECO D3


Interface required: 29-0285 (internal) or 29-0373 (external)


Connect the interface 29-0285

Input:

EXT (iMETOS 3.3)
EXT1 (ECO D3)



Connect the sensor to the interface 29-0285

Input:

Channel A
Channel B

Wiring:

DT = Data (white)
PW = Vcc (red)
GD = Ground (green)



Connect the interface 29-0373

Input:

RS485 (iMETOS 3.3)
SENS. CHAIN (ECO D3)

Wiring:

BR = Brown
GR = Green
YE = Yellow
WH = White
BR = Bare



Connect the sensor to the interface 29-0373

Input:

SDI12

Wiring:

SUP = Vcc (red)
DT = Data (white)
GND = Ground (green)



Connect to RadioNode

RFRN13 iMETOS RadioNode Drill & Drop

SD51 iMETOS RadioNode Drill & Drop 

Order number 700243 (EU 869MHZ) / 700244 (US 915MHZ)

 