This article explains how to create a transmission log from a METOS 5 station and send it to METOS Support when requested. Providing a correct log helps our support team diagnose issues faster and reduce resolution time.
Important Notes Before You Start
Before generating and sending a transmission log, please ensure:
Your METOS 5 is running the latest firmware
The station battery is charged to approximately 6.5V
You follow all steps exactly as described
⚠️ Logs sent without the required settings may delay troubleshooting.
Prerequisites
Before you start, ensure you have:
A computer with PI Service Terminal installed
A mini USB cable that supports data transfer
Physical access to the METOS 5 station
A charged battery (~6.5V)
No jumper is required for this operation
Step 1: Install PI Service Terminal
Download the latest release of PI Service Terminal - LINK
Install the application - LINK
Launch the application on your computer
Step 2: Connect the METOS 5 Station
Plug the METOS 5 station into your computer using a USB cable
Switch on the METOS 5 station
In PI Service Terminal, ensure the following options are enabled:
✅ Save to Log
✅ Timestamp
Open Menu → Settings and activate Advanced Mode
Password:
PIST2022
⚠️ These settings are essential for the METOS Support team to analyze the log correctly.
Click Connect
Step 3: Wait for the Connection to Complete
After startup, the station will initiate communication automatically
Wait until the process finishes
The connection process may take several minutes
? If nothing appears on the screen:
Disconnect the battery and solar panel
Wait 30 seconds
Reconnect both and repeat the steps above
Step 4: Retrieve and Send the Log
In PI Service Terminal, open Advanced Functions from the left menu
Select METOS 5
Tick Auto-generate METOS 5 Logs
Wait while the log is generated
Log Details
The log is automatically saved when Save to Log is enabled
The file location is displayed in the status bar of PI Service Terminal
To send the log
You can send the log in one of the following ways:
Open the folder shown in the status bar or
Click Send in PI Service Terminal
Fill in the required fields
Send the log via email
Common Issues & Solutions
❌ No COM Port Appears
Check the following:
Battery voltage is approximately 6.5V
Battery cable is properly connected
The USB cable supports data transfer (some cables are power-only)
Need Help?
If you encounter issues during this process or are unsure whether your log was created correctly, please contact METOS Support Center and include the transmission log in your request.
Was this article helpful?
That’s Great!
Thank you for your feedback
Sorry! We couldn't be helpful
Thank you for your feedback
Feedback sent
We appreciate your effort and will try to fix the article